High Thrust Air Cylinder

     
Pneumatic Power Cylinder

Inching (Necessary option : Stop valve, Optional code : V*)

Optional code (V*) is not the same as operation valve code (V*).







The position adjustment of die at the time of the start up, the position adjustment of die and workpiece, the position adjustment after die replacing.
Do OFF and ON the solenoid valve of the fast feed and the stop valve at the same time when the piston rod advances.
Do OFF and ON the solenoid valve of the stop valve when the piston rod retracts.

- Note -
Use a 2 position single solenoid valve for the fast feed valve. It need a upward thrust at the time of stop.